CAN Bus Diagnostics
The C8 top modules talk over GM high-speed GMLAN (HS-CAN, 500 kbps). When the top quits with lost-communication U-codes, the bus itself is a suspect. This page covers the common CAN faults and how they show up with a PicoScope: CAN-H/CAN-L traces, the differential, serial decoding, and eye/mask testing.
Contents
Normal values · PicoScope hookup · Protocol errors · Short-circuit faults · Physical-layer faults
Quick reference: normal HS-CAN values
| Measurement | Normal (typical) |
|---|---|
| Bit rate (C8 HS-GMLAN) | 500 kbps, 2 µs per bit |
| Recessive CAN-H / CAN-L | ~2.5 V / ~2.5 V |
| Recessive differential | ~0 V |
| Dominant CAN-H | ~3.5 V |
| Dominant CAN-L | ~1.5 V |
| Dominant differential | ~2 V (≥1.5 V) |
| H–L resistance, battery disconnected | ~60 Ω (two 120 Ω in parallel) |
| ~120 Ω | One terminator open or missing |
| ~0 Ω | H shorted to L |
| H or L to ground / B+ | High resistance (no short) |
Exact values vary by transceiver and load. Always confirm against GM service information for the circuit you are testing.
How to hook up a PicoScope
- Find a convenient access point: the DLC (OBD-II) connector or a module connector on the HS-CAN circuit. Confirm which pins/circuits are HS-CAN from GM wiring diagrams; don't guess.
- Channel A to CAN-H, channel B to CAN-L, both referenced to a good chassis/battery ground. Use back-probes or a breakout lead; never pierce insulation.
- Start at 1 V/div (±5 V range, DC coupled) and 2–5 µs/div for bit-level detail, or a longer timebase (ms) to see whole frames and bus load. Use ±20 V if you suspect a short to B+.
- Add a math channel A−B to view the differential signal.
- Enable serial decoding: CAN, 500 kbps, source on the CAN-H (or differential) channel, threshold around the midpoint. Use the decoder table to filter by ID and error type.
- Use triggers on error frames and the mask/eye-diagram tools across many frames to catch intermittent faults.
- For resistance checks, disconnect the battery and let modules sleep first; a powered bus gives meaningless ohm readings.
Protocol errors
Protocol errors are detected by the CAN controllers themselves; the scope shows the result (error flags, retransmissions) and the serial decoder labels the error type.
Missing ACK / ACK error
- What it is
- The transmitter sends the ACK slot recessive and expects at least one receiver to overwrite it dominant. If nobody does, the transmitter flags an ACK error.
- On the scope / in the decode
- ACK slot stays recessive (both lines ~2.5 V), followed by an error flag and the same frame retransmitted over and over. Decoder shows repeated identical IDs tagged ACK error.
- Likely causes
- The transmitter is the only node on the bus (others unpowered, open wire, unplugged connector), wrong baud rate on the other nodes, or the scope/tool is on an isolated segment.
- How to test
- Confirm other nodes are powered and awake. Check continuity of CAN-H/CAN-L to each node. A node that ACKs nothing is often on a different baud rate or disconnected.
Bit stuffing error
- What it is
- CAN inserts an opposite bit after five identical bits. Six identical bits inside a frame (outside the error flag) is a stuff error.
- On the scope / in the decode
- Six or more equal bits where the decoder expected a stuff bit; decoder tags Stuff error, then an error frame follows.
- Likely causes
- Noise or ringing flipping a bit, bit-timing/sample-point mismatch between nodes, marginal edges from bad termination or long stubs, a failing transceiver.
- How to test
- Check eye/mask quality at several points on the bus, compare sample points, check termination and stub length. Stuff errors clustered at one node point to that node or its wiring.
CRC error
- What it is
- Receivers compute a 15-bit CRC over the frame; a mismatch with the transmitted CRC is a CRC error, signalled after the ACK delimiter.
- On the scope / in the decode
- Frame often looks clean at a glance; the decoder marks CRC error, the ACK is withheld by the failing receiver, and an error frame follows.
- Likely causes
- Bit corruption from noise, EMI, reflections, ground offset or a weak transmitter; sometimes intermittent connectors.
- How to test
- Look for glitches with persistence mode or a mask test across many frames. Probe at the complaining node vs. the sender to see where corruption appears.
Form error
- What it is
- A fixed-format bit (CRC delimiter, ACK delimiter, end of frame) was the wrong level.
- On the scope / in the decode
- A dominant bit where the frame format requires recessive; decoder shows Form error.
- Likely causes
- Noise, reflections, a node with wrong timing, or a node transmitting at the wrong time.
- How to test
- Same as CRC/stuff: check signal integrity, timing, and isolate nodes by unplugging one at a time.
Bit error
- What it is
- A transmitting node reads back a different level than it sent (outside arbitration and the ACK slot).
- On the scope / in the decode
- Sent recessive, bus read dominant (or the reverse) mid-frame; error frame starts on the next bit.
- Likely causes
- Another node driving at the wrong time, short or leakage pulling the bus, failing transceiver, severe noise.
- How to test
- Watch which node is transmitting (ID) when errors occur; disconnect suspects; check line-to-ground and line-to-B+ resistance.
Arbitration lost
- What it is
- Normal behaviour, not a fault: when two nodes start together, the lower (more dominant) ID wins bit-by-bit and the other backs off.
- On the scope / in the decode
- At the losing bit the losing node sent recessive but sees dominant; it stops and retries later. No error frame.
- Likely causes
- Expected on a busy bus. Only a concern if a low-priority node is starved (very high bus load) or a node is babbling with a high-priority ID.
- How to test
- Measure bus load in the decoder statistics; look for one ID flooding the bus.
Error frames (error-active / error-passive)
- What it is
- An error-active node signals an error with 6 dominant bits, plus an 8-bit recessive delimiter. After its transmit or receive error counter passes 127 it becomes error-passive and its flag is 6 recessive bits instead, so it can no longer disrupt the bus.
- On the scope / in the decode
- Active: a 6-bit dominant block (often stretched to up to 12 when other nodes echo it) after the faulty point. Passive flags are invisible on the bus; you just see retransmits and gaps.
- Likely causes
- Any of the errors above. Frequent error frames mean a physical-layer or timing problem.
- How to test
- Use the decoder's error-frame filter/trigger to capture the frame just before the error and look at its waveform.
Bus-off
- What it is
- When a node's transmit error counter exceeds 255 it goes bus-off and stops participating until reset/recovery.
- On the scope / in the decode
- That node's IDs disappear from the decode; the bus may continue normally for other nodes, or go quiet if it was the only sender. Scan tool typically shows lost-communication U-codes (e.g. U0100-class) in other modules.
- Likely causes
- Persistent transmit errors: bad transceiver, wiring fault on its branch, wrong baud rate, power/ground problem at the module.
- How to test
- Check module power and grounds, its CAN branch continuity and resistance, then watch for its IDs after a key cycle.
Short-circuit faults
Shorts usually take the whole bus down. Measure resistance with the battery disconnected, then isolate by unplugging modules and splitting the harness.
CAN-L shorted to ground
- What it is
- CAN-L held at ~0 V by a short to chassis ground.
- On the scope / in the decode
- CAN-L flat at ~0 V. CAN-H still toggles but its levels are pulled down. Differential is wrong in recessive (not ~0 V), so many transceivers fail or limp; decoding usually fails or shows heavy errors.
- Likely causes
- Chafed harness to body metal, pinched wire, water in a connector, failed transceiver.
- How to test
- Battery disconnected: measure CAN-L to ground (should be high, kΩ to MΩ, not near 0 Ω). Unplug modules one at a time until the short clears to isolate harness vs. module.
CAN-H shorted to ground
- What it is
- CAN-H held at ~0 V.
- On the scope / in the decode
- CAN-H flat near 0 V, CAN-L dragged low; differential is negative/zero; communication normally stops.
- Likely causes
- Chafed wire, crushed harness, contaminated connector, failed module.
- How to test
- Battery disconnected: CAN-H to ground resistance. Split the bus at connectors and unplug modules to find the segment.
CAN-H shorted to battery positive
- What it is
- CAN-H pulled to system voltage (~12–14 V).
- On the scope / in the decode
- CAN-H flat at battery voltage (use a ±20 V range or it clips). CAN-L may still toggle. Bus usually down.
- Likely causes
- Harness chafed against a B+ feed, wrong repair splice, failed module.
- How to test
- Key off: measure CAN-H to B+ resistance and CAN-H voltage with modules unplugged one by one. Remove fuses on suspect circuits to see if it drops.
CAN-L shorted to battery positive
- What it is
- CAN-L pulled to battery voltage.
- On the scope / in the decode
- CAN-L flat at ~12–14 V, CAN-H toggles but the differential is wrong; bus usually down.
- Likely causes
- Same as above: chafing against a powered circuit, bad splice, module failure.
- How to test
- Measure CAN-L voltage with key off/on; isolate by unplugging modules and splitting the harness.
CAN-H shorted to CAN-L
- What it is
- The two lines are tied together.
- On the scope / in the decode
- Both traces sit on top of each other near 2.5 V; differential collapses to ~0 V; no valid frames. Resistance across H–L reads near 0 Ω.
- Likely causes
- Crushed twisted pair, water/corrosion bridging pins, failed transceiver.
- How to test
- Battery disconnected: H–L resistance ~0 Ω confirms. Unplug modules/segments until it returns to ~60 Ω.
CAN-H and CAN-L reversed (swapped wiring)
- What it is
- At one node or segment CAN-H and CAN-L are crossed.
- On the scope / in the decode
- Probing the swapped section, the trace labelled CAN-H drops to ~1.5 V when dominant and CAN-L rises to ~3.5 V (mirror image); differential is negative. Decoder shows errors or no frames; the swapped node can't talk and can disturb the others.
- Likely causes
- Repair splice crossed, wrong connector pinout on a replacement or aftermarket harness, mis-pinned terminal.
- How to test
- Probe at the node and compare polarity to a known-good point. Verify pinout against GM service information and check recent repair splices.
Physical-layer faults
Dominant bus stuck
- What it is
- The bus is held in the dominant state (CAN-H high, CAN-L low) permanently.
- On the scope / in the decode
- Flat ~3.5 V / ~1.5 V, ~2 V differential, no edges; decoder sees nothing or continuous error.
- Likely causes
- A transceiver stuck transmitting (failed module or TXD pin stuck low), or a short pulling lines apart.
- How to test
- Unplug modules one at a time; the one that frees the bus is the culprit. Check the bus voltages with each removed.
Recessive stuck / open circuit
- What it is
- A break in CAN-H or CAN-L, or a node that never drives dominant.
- On the scope / in the decode
- One line floats or shows a weak, noisy copy of traffic at the far side of the break; nodes beyond the open can't communicate. If a whole segment is cut, you see recessive ~2.5 V only.
- Likely causes
- Broken wire, pushed-back terminal, corroded connector, open splice.
- How to test
- Battery disconnected: H–L resistance reads ~120 Ω (only one terminator reachable) instead of ~60 Ω. Continuity check each line end-to-end; wiggle-test connectors while watching the scope.
Termination problems
- What it is
- A HS-CAN bus has a 120 Ω terminator at each end, giving ~60 Ω across H–L.
- On the scope / in the decode
- Missing termination: slow edges, ringing and overshoot, more errors at higher bus load. Too low (extra or shorted terminator): reduced differential amplitude.
- Likely causes
- Terminating resistor lives in a module or connector; unplugged/failed module, open wire to one end, or extra terminator added.
- How to test
- Battery disconnected, wait for modules to sleep, measure H–L: ~60 Ω correct, ~120 Ω one terminator missing/open, ~40 Ω or lower extra load, ~0 Ω shorted.
Baud rate mismatch
- What it is
- A node or tool is configured for a different bit rate than the bus. C8 high-speed GMLAN runs at 500 kbps.
- On the scope / in the decode
- Bit widths don't match the expected 2 µs at 500 kbps (e.g. 4 µs at 250 kbps); the decoder shows nothing valid or constant errors; the mismatched node's frames cause error frames.
- Likely causes
- Wrong module programmed or replaced, aftermarket device, wrong tool/decoder setting.
- How to test
- Measure the narrowest bit width with cursors: bit rate = 1/bit time. Set decoder baud to match and confirm clean decode.
Node not responding / no communication
- What it is
- A module does not send or answer.
- On the scope / in the decode
- Its IDs are missing from the decode; bus may be idle at recessive ~2.5 V on both lines if no node is talking. Other modules set lost-communication U-codes (U0100-class).
- Likely causes
- Module power or ground missing, blown fuse, open CAN branch, module asleep or failed, bus-off.
- How to test
- Check power/ground under load at the module connector, then CAN-H/CAN-L at the connector with the scope while the bus is awake.
Noise / EMI and ringing
- What it is
- Unwanted energy coupled into the bus.
- On the scope / in the decode
- Fuzz or spikes on both lines; in a properly twisted pair much of it is common-mode and cancels in the differential (math channel A−B). Ringing at edges = reflections from bad termination or long stubs.
- Likely causes
- Untwisted repairs, routing near ignition/injector/motor wiring, poor grounds, missing termination.
- How to test
- Use a math channel H−L and an eye/mask test: errors that survive in the differential matter; common-mode-only noise usually doesn't.
Ground offset
- What it is
- Module grounds at different potentials shift where that node sees the bus.
- On the scope / in the decode
- Both lines shifted up or down together relative to scope ground; differential still ~2 V. Transceivers tolerate a limited common-mode range; beyond it errors appear.
- Likely causes
- Corroded or loose ground straps, high-resistance ground eyelets, heavy current through shared grounds.
- How to test
- Voltage-drop the module ground to battery negative under load; compare bus recessive level measured at different modules.
Bad recessive voltage
- What it is
- In recessive both lines should sit at ~2.5 V with ~0 V differential.
- On the scope / in the decode
- Lines split apart at idle, or both biased well away from 2.5 V; decoder errors on recessive bits.
- Likely causes
- Leakage path to ground or B+, failing transceiver, water in connector.
- How to test
- Measure each line to ground with the bus idle/awake; unplug modules one at a time to see which one restores ~2.5 V.